<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-06 18-12-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 69 kHz 15489 0,7554
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,5 dBr 3,68 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 12 kHz % above 76 kHz: 0,7554 Acquired: 2025/07/06 18.11.49 Total samples: 15489 Equivalent time: 0:12:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,1 dBr MIN: 2,5 dBr AVE: 3,68 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2025/07/06 18.11.48) 17.58 18.00 18.02 18.04 18.06 18.08 18.10 0 2 4 6 Pm [dBr]